GXT3-10000T230
  • GXT3-10000T220 500x500

Emerson Liebert® GXT3-10000T220™

Call for Price

In Stock

Quick Overview

Emerson Liebert® GXT3-10000T220™

Compare
Category: .

Product Description

The Liebert GXT3-10000T220 is an on-line UPS. An on-line UPS continuously conditions and
regulates its output voltage whether utility power is present or not. It supplies connected equipment
with clean sinewave power. Sensitive electronic equipment operates best from sinewave power.

The liquid crystal display is used for controlling operation of the UPS, as well as monitoring its
status, condition, alarm status and history. For ease of use, the Liebert GXT3-10000T220 features a
light-emitting diode (LED) display to indicate operational status. It also provides self-diagnostic tests,
a combination On/Alarm Silence/Battery Test button, a Standby button, user configurable program
and two levels of alarms when the unit is operating on battery.

The Liebert GXT3-10000T220 has an interface port for communication between the UPS and a
network server or other computer system. This port provides detailed operating information including
voltages, currents and alarm status to the host system when used in conjunction with Liebert’s
MultiLink® software. Liebert MultiLink software may also control UPS operation remotely.

Additional Information

Specification :
UPS Part Number

GXT3-10000T220

Dimensions, in. (mm) :
Unit, W x D x H

31.5 x 11.81 x 26.57 (800 x 300 x 675)

Shipping, W x D x H

41.8 x 16.7 x 34 (1062 x 426 x 866)

Weight, lb (kg) :
Unit

308 (140)

Shipping

428 (194)

Input AC Parameters :
Nominal Operating Frequency

50 or 60Hz (Factory Default = 60)

User Configurable VAC

120 / 208 / 220 / 240

Operating Voltage Range Without Battery Operation

100 – 185 ±5VAC

Maximum Allowable VAC

280

Input Frequency Without Battery Operation

40 – 70Hz

Input Power Connection

BYP, L1, L2, GND

Output AC Parameters :
Factory Default, VAC

208

Output Connections

Hardwire Terminal Block (Output: (GEC, X1, X2, X3, X4, GND) Bypass: L1, L2, GND)

Frequency

50Hz or 60Hz, Nominal

Waveform

Sinewave

Main Mode Overload

>200% for 5 cycles; 151 – 200% for 1 second; 131-150% 10 seconds; 105 – 130% 1 minute

Battery Parameters :
Type Battery

Valve-regulated, non-spillable, lead acid

Quantity x V

20 x 12V

Battery Mfr. / Part #

CSB HR1234R or Panasonic UP-RW1245

Recharge Time (Internal Batteries)

3 hr. to 90% capacity after full discharge into 100% load

Bypass Protection Limits :
Maximum Bypass Current

50A

Re Enable Bypass Operation

If input voltage returns to within ±8% of nominal output voltage

Disable Bypass Operation

When the input frequency prevents synchronous operation

Environmental :
Operating Temperature, °F (°C)

32 to 86 (0 to 30) with 0.9 pf, 86 to 104 (30 to 40) with 0.8pf

Storage Temperature, °F (°C)

5 to 122 (-15 to 50)

Transportation, °F (°C) :
Relative Humidity

0-95% non-condensing

Operating Elevation

Up to 3281 ft (1000m) at 80°F (27°C) without derating

Audible Noise

<55 dBA at 3.3ft (1m) from rear; <50 dBA at 3.3ft (1m) from front or sides

Agency :
Safety

UL 1778, c-UL

RFI/EMI

FCC Part 15, Subpart B, Class A

Surge Immunity

IEC/EN 61000-4-5, ANSI C62.41 (for North America)

Transportation

ISTA Procedure 1B

Reviews

There are no reviews yet.

Be the first to review “Emerson Liebert® GXT3-10000T220™”

Related Products

 
Free Shipping
Lorem ipsum dolor sit amet, consectetur adipisicing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua domenus orioneu.
 
Customer Support
Lorem ipsum dolor sit amet, consectetur adipisicing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua domenus orioneu.
 
30 days money back
Lorem ipsum dolor sit amet, consectetur adipisicing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua domenus orioneu.
X