Specification :
UPS Part Number

GXT3-10000T230

Nominal input voltage, VAC

230VAC Single Phase (L,N,G) 230/400 Three Phase (L1,L2,L3,N,G)

Input phases, VAC

Single phase or three phase, automatic detection

Input voltage

176-280V for 1×1, 304-485V for 3×1

Nominal frequency, Hz

50/60 Auto selection

Maximum Input Power (Nominal Input Voltage, R Full Load) :
Float (kVA) 1

9900VA for 1×1; 10100VA for 3×1

Recharge (kVA) 2

10460 VA for 1×1; 10900 VA for 3×1

Power factor (at nominal V, with R full load)

Single Phase Input: not less than 0.99, Three Phase Input: not less than 0.95

Input current distortion (with R full load) THDi 3

Single Phase Input: < 5%, Three Phase Input: < 31%

Inrush current (A) (typical)

67.5

Battery Charger :
Battery nominal voltage, VDC

240

Battery charger input voltage range, VDC

100-276

Output voltage, V

Multi-stage charging method

Charging time to 90% capacity in inverter mode, hr.

3

Charger output current (ADCaver) (Amps)

2.8A

Static Switch :
Nominal frequency

50/60 Hz auto selection

Frequency tolerance

±3.5 Hz

Voltage tolerance

100V – 280V

Overload :
Overload > 100%

Audible alarm

In phase switching time direct/conditioned (ms)

Zero break

Condition/direct

Zero break

105% to 130%

1 minute

131% to 150%

10 seconds

151% to 200%

1 second

>200% (impact load)

At least 5 cycles

Maximum noise level at 1 meter front side normal mode and battery mode

≤ 50dBA

Degree of protection

IP20

Physical Characteristics :
Battery :
Optimum battery temperature, °C (°F)

15 – 25 (59-77)

Power output

8.5kW

Recommended number of cells

120

End of discharge

200VDC

Battery number

20

Discharging time

5 minutes

Auto battery missing detection

Yes

External Battery Cabinet

1Set / 2Set

Battery type

HR 1234W F2 12V / 8.5Ah

Battery number, pcs.

40 / 80

Dimensions, W x D x H, mm (in)

300 x 675 x 800 (11.8 x 26.6 x 31.5)

Color

Black

Weight with integrated batteries, kg (lb)

162 (357)

Reviews

There are no reviews yet.

Be the first to review “Emerson Liebert® GXT3-10000T230”

Related Products

 
Free Shipping
Lorem ipsum dolor sit amet, consectetur adipisicing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua domenus orioneu.
 
Customer Support
Lorem ipsum dolor sit amet, consectetur adipisicing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua domenus orioneu.
 
30 days money back
Lorem ipsum dolor sit amet, consectetur adipisicing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua domenus orioneu.
X