SURVEY and Data Collection W O R K 

The Survey of Data Centres need Importent Information for Basic Design to Match Customer Need and Goal of New Data Centres

Type of Survey Type of Data 
Informamation Gathering Overall Data Center Layout and Space Utilization
Current Physical Infrastructure System 
The Current Objectives of Data Center
Future Requirement of The Data Centres
Key Phisical Infrastucture features and capabilities needed to support  the Current and the Future Goal for the Data Centres
On Site Evaluation  Overview 
Conduct Visual Inspection of the Existing physical infrastructure to ecvaluate : 
1. Overal Layout and Space Utilization 
2. Thermal Management 
3. Power Distribution System 
4. Cabling 
5. Cable Routing Path Ways 
6. Racks and Cabinet 
7.Telecommunication Grounding and Bonding  
   System
8. Labeling and Administration 
Overal Layout and Space Utilization 
1. Overal Size and Conditio of Data Centre room . 
    It's Suitable for the Operations
2. Room Layout 
3. Capacity for Expantion
Thermal Management and Coding System 
1.  The Overal layout and room conditions, Including Hot Aisle and Cold 
     Aisle Configuration, Air Suply and Return Locations, Hot Spots,  and 
     overal air flow , to and from air handling unit 
2. Raised Floor Depth , Under Floor Obstruction , Perforated tile 
    Locations,  sealing of floor tile cut outs and the ability to reconfigure
    tiles to improve airflow
3. Drop Ceiling height , Overhead Plenum obstruction , ceiling grate 
    locations, and the ability to adjust or reposition ceiling grates to 
    imporve airflow.
4. The use of blanking panels, airdams , cable entry/exit , Hot Aisle/Cold      Aisle , ducted exhaust system , and other airflow recirculation control 
    methods.
5. Location , Alignment , Unobstruction airflow , and proper operations 
    of computer Room Air Condition (CRAC), Computer to Room Air 
    Handler (CRAH) , In Row Coolers and Others Cooling System 
    Equipment
6. Overall Ratio of Cooling Capacity to IT Equipment Thermal Load 

SURVEY and Data Collection W O R K 

NEXT ......

Type of Survey Type of Data 
POWER DISTRIBUTION SYSTEM 
1. Cabinet level Power outlet availibilty, Power Outlet Unit (POU) 
    Capacity, IT Equipment Compatibility, Redundancy , Alignment with 
    all Data Center Tier Level , and ability to handle aditional 
    deployment  and future growht. 
2. POD or ROW Level Power Distribution methodology ,access ability ,  
    Reconfiguration agility , Redudancy , alighment with all tier level and 
    capacity for expantion
3. Overall Data Center Power System Topology , Redundancy, Tier 
    Level, and Expandability .
4. Stand By Power System Configuration , Load Capacity , Backup 
    Support Duration, and capability for future growth. 
CABLING 
1. Stack management and Stand Relief
2. Bend Radius Control 
3. Cable Routing and Termination 
4. Cable Density 
5. Cable Installation Practice 
6. Labeling of Cable with EIA/TIA Standard
7. Separation of Coper data Cabling and Power Cabling 
8. The Organizational Cable Structure , Topology, Bandwith  of your 
    Cooper and Fiber Optic System .
CABLE ROUTING PATHWAYS
1. Patways Design and Installation 
2. Cable Protection 
3. Protection of Fiber Cords
4. Fill Capacity 
5. Patways Support
6. Waterfalls
7. Stack Management 
8. Bonding 
9. labeling 
RACKS and CABINET 
1. Space of Racks and Cabinet 
2. Physical Insllation Active Equipment in rack or Cabinet 
3. The Risk Physical damage of Equipment 
4. Thermal Management on Rack 
5. wheather  cabinet and Rack Air Flow 
6. Internal Bonding of Rack and cabinet 
7. Support for Expandble for the future 
TELECOMMUNICATION GROUNDING AND BONDING 
1. Room Level Bonding Practices Including Mess Common Bonding 
    Network (MCBN, also refferd to mess BN) Construction and 
    Connection beetwen MCBN and the Telecommunication Bonding 
    Bacbone (TBB).
2. Bonding in the racks Cabines including Equipment Bonding jumpers, 
    Rack and Cabinet Bonding Conductor, Busbar, Bonding Strips and 
    Bonding Conection Methods.
3. Electro Static Discharge (ETD) protection 
LABELING ADMINISTRATION 
1. Overall Room Labeling 
2. Rack and Cabinet Labeling 
3. IT Equipment , Panels and Enclosure Labeling 
4. Port and Permanent Link Labeling 
CLIENT RESPONSIBILITY  1. Client Povide unlimited access to data center
2. Client allow to Photograp the Conditons of Data Center
3. Client Provide any necesary information 
4. Client Designated PIC for Communication 

Data Center Frame Works

1

Data Center Location ANSI/TIA 942

2

Physical Infrastructure  ANSI/TIA 942

3

Building Management (EN 15221)

Facilities Management (EN 15221)

4

ICT Infrastructure 

5

ICT Service Management

ISO/IEC 2000 

6

Organization 
TC 260

7

Governance and Risk Compliance 

ISO/IEC 38500

8

Project Management 

PRINCE.2/PMBOK

9

Security Management 

ISO/IEC 27001